MORPHEUS M

The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients.
The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.

The unit for anaesthesia MORPHEUS M is completed with:
– mechanic gas mixing system
– electronic lung ventilator with 12” TFT colour display
– valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
– SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
– gas supply group

Description

Ventilator module

The lung ventilator incorporates a 12″ TFT high resolution colour display with membrane keyboard and encoder.

Ventilation modalities:
APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.

Measured parameters:
PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2
Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri

Displayed ventilation curves:
– Paw
– Flow
– Volume
– Loop (Volume/Paw ; Volume/Flow)
Reading is made through an exclusive SIARE stérilizable flow sensor operating by magnetic induction and positioned inside the expiratory valve of the breathing system. This technological development allows to eliminate all management costs raising from continuous replacement off low sensors positioned directly on the patient’s mouth and makes the device unique in its gender.

Adjustable parameters:
– O2 built-in Mixer device from 21% to 99%
– I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1
– Inspiratory Flow
– PEEP
– Breathing Rate
– Minute Volume;
– Tidal Volume
– Inspiratory Pressure Limit
– Inspiratory Pause
– Inspiratory Time
– Trigger

Mechanic flowmeter module


3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).

Breathing system

The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.
All Siare valves group are equipped with an automatic warming system avoiding humidity in the patient circuits and permit to deliver fresh gas to the patient at optimal temperatures.

The breathing system is made of:
– Calibrated APL valve
– Fresh gas collecting bag
– O2 cell for reading of FiO2
– Removable 1 kg soda lime canister
– Manually inspectionable bellows jar
– Safety valve for ambience air suction in case of fresh gas failure
– Flow transducer inside the group located on the expiratory line.

Optional accessories

11054 AIRPAK 54 stand-alone medical air compressor
100150/IDF Isoflurane Vaporizer
100148/IDF Fluo-Halotane Vaporizer
100145/IDF Sevoflurane Vaporizer
100151/IDF Desflurane Vaporizer
A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto
For other accessories, please refer to the price list in force.

Versions

OM3.S5 MORPHEUS M: Computerized anesthesia machine for adults, children and newborns equipped with 3-flow mechanical mixing system with 5 low flow rates (O2, N2O, Air)
OM3.M MORPHEUS M LIGHT: Computerized anesthesia machine for adults, children and newborns equipped with  3-gas mechanical type mixing system (O2, N2O, Air)
OM3.SE MORPHEUS E: Anaesthesia machine for adults, children and new-born babies with electronic as mixing device O2/N2O/AIR with flow resolution.
OM3.A3s MORPHEUS LT: Anaesthesia machine for adults, children and new-born babies with electronic as mixing device O2/N2O/AIR with flow resolution.